Filter Replacement
A lter, located in the tip of the wand, blocks moisture and other
contaminants from the sensor. When this lter becomes wet, it
restricts the ow of air and must be replaced.
To replace the lter:
1. Unscrew and remove the tip of the sensor to expose the white
lter.
2. Remove and discard the lter.
3. Position a new lter in the tip so the round end of the lter is
closest to the tip of the wand.
NOTE:UseonlyTIFsuppliedreplacementlters.
Storage
The battery should have a 40%-50% charge during prolonged
storage of a month or longer. The correct storage environment is
critical to battery life.
Storage environment: <80% RH for detector and battery.
For 80% battery recovery:
-4ºF (-20°C) to 140ºF (60°C) less than 1 month
-4ºF (-20°C) to 11F (4C) less than 3 months
-4ºF (-20°C) to 68ºF (20°C) less than 1 year
NOTE:Batterylifewillbereducedsignicantlyifthebatteryis
stored with a full charge and/or at high temperatures.
Accessories and Replacement Parts
Optional Accessories
Order No.
Extension Probe (9 inch) ......... TIFIR-4
Rigid Extension Probe ............. TIFIR-5
Replacement Parts
Order No.
100-240 VAC Charger ............. TIFIR-6
12 VDC Charger ...................... TIFIR-7
Filters (5) and O-rings (3) ........ TIFIR-8
Lithium-ion Battery .................. TIFIR-9